The use of panic hardware and or fire exit hardware is required by the international building code ibc and nfpa 101 the life safety code depending on which code and which edition of the code is being referenced.
Exit door hardware requirements.
It will need distinctive colors and easily seen or reflectable when facing the path of egress.
Each door in a means of egress from an occupa ncy of group a or e having an occupant load of 100 or more and any occupancy of group h 1 h 2 h 3 or h 5 shall not be provi ded with a latch or lock unless it is panic hardware or fire exit hardware.
Each fire door including its frame and hardware must be listed or approved by a nationally recognized testing laboratory.
If balanced door s are used and panic hardware is required the panic hardware shall be of the.
Code publications define panic hardware as a door latching assembly incorporating a device that releases the latch upon the application of a force.
Basically if a door doesn t have a lock with a push pull or a latch the door is not legally required to need panic hardware.
Purpose all exit doors shall be easily opened from the interior without the use of a key combination or any special knowledge or effort.
Nfpa emergency exit door requirements for marking.
Door lock heights on exit doors fire doors path of travel doors and disabled access doors now have a standardised lock height of 900mm 1100mm.
Subsequently place these exit signs only on emergency exit doors and doors leading to an exit.
All exit paths must have a clearly recognizable exit sign.
The ibc 2006 and 2009 editions requires panic hardware and or fire exit hardware on egress doors with an occupant load of 50 people or more in the following.
The exception being locks in childcare facilities which may be 1500mm 1650mm high as necessary.
Panic hardware cannot be used on a fire door because of the danger of trapping people inside during a fire.
Means of egress exit hardware requirements town of brighton office of the fire marshal october 2018.
And in addition lit by a reliable light source.
Sometimes panic hardware is called fire exit hardware or they may be referred to as egress doors.
When panic hardware is used on fire doors it must be fire exit hardware that has been tested per ul 10c positive pressure fire tests of door assemblies or another fire test standard and the.
An opening into an exit must be protected by a self closing fire door that remains closed or automatically closes in an emergency upon the sounding of a fire alarm or employee alarm system.